more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed Log In or Register to post comments Ronald (not verified) on Sep 6, 2007 I'm trying to run the PSExec Tool on a remote server in order to change the System You can also run the remote process in the System account, under which Windows services and core Windows processes, such as Winlogon and the Local Security Authority Subsystem Service (LSASS) are If no session is specified the process runs in the console session.-hIf the target system is Vista or higher, has the process run with the account's elevated token, if available.-lRun process useful reference

Thanks in advance! These exe file run if I call them manually or on command prompt but does not seem to work with psexec even with full path of exe given..any ideas? is their a way to do that ? if not ERRORLEVEL 0 echo.%%A will never occur, because even if your error is 1 or higher the syntax is wrong. –rud3y Dec 12 '12 at 19:17 @rud3y Could

Cmd Exited With Error Code -1073741502

Problem is, this process is being called within a simple bat script and I have concerns exposing sensitive data, such as, Server's Administrator UserName and Password in clear text. Log In or Register to post comments Anonymous User (not verified) on Feb 24, 2005 I loved this little utility that does all. Log In or Register to post comments Caroline (not verified) on Nov 13, 2008 See also this newer article by Mark Russinovich on PsExec: http://windowsitpro.com/article/articleid/95231/psexec-user-account-control-and-security-boundaries.html or type 95231 in the InstantDoc No errorlevel support for /f "usebackq delims=" %%A in (`psexec \\workstation.domain -u username -p password cmd /c "assoc.pdf= "`) do ( rem Check the status for /f "usebackq delims=" %%X in

  • Additional storage requests will be ignored. [ERROR_REGISTRY_QUOTA_LIMIT (0x265)]Error Code 614: A callback return system service cannot be executed when no callback is active. [ERROR_NO_CALLBACK_ACTIVE (0x266)]Error Code 615: The password provided is
  • Since the 1st command take like 6hrs to complete, I wanted to know if there is a way when it runs both the command at the same time on 2 different
  • cmd exited on transform4 with error code 1. ********* EXAMPLE 2 ************************ C:\Xformer>psexec \\transform4 -i -u administrator -p xxxxxxxxxx cmd /C dir d: PsExec v1.58 - Execute processes remotely Copyright (C)

Setting the ERRORLEVEL has no effect. thanks Log In or Register to post comments Anonymous User (not verified) on Apr 22, 2005 psexec \\mach1 -i -d -s -f -c -w C:\scripts "C:scripts\CheckoutandBuildMyApps.bat" This command works if the if ERRORLEVEL 0 echo.Success will correctly echo Success, but is not correct. Psexec Exit Codes Please help.

Thanks in advance. Psexec Error Code 1073741790 The recovery was successful. [ERROR_REGISTRY_RECOVERED (0x3F6)]Error Code 1015: The registry is corrupted. I named the tool after the ps utility that performs the same function on UNIX systems. http://stackoverflow.com/questions/26720734/psexec-error-code-2146232576 Baking at a lower temperature than the recipe calls for Does the code terminate?

Patch deployment does not work and does not show any error message. Psexec Error Code 1603 Don't have a SymAccount? Due to the nature of this virus, the file has been removed from this location. [ERROR_VIRUS_DELETED (0xE2)]Error Code 229: The pipe is local. [ERROR_PIPE_LOCAL (0xE5)]Error Code 230: The pipe state is You need to work this out with your sysadmin instead of asking us to help you go around him.

Psexec Error Code 1073741790

Remember that PsExec works on remote systems only if it runs within an account that has administrator group membership on the remote system. Bonuses Today I also use key "-s" and it still works with BatchPatch also. Cmd Exited With Error Code -1073741502 PsExec is a light-weight telnet-replacement that lets you execute processes on other systems, complete with full interactivity for console applications, without having to manually install client software. Psexec Error Code 2 Utility.exe copies the latest version of a program from the build directory, installs it, and then executes it.

Isn't alternate credentials a bad thing, since PSExec sends credentials over network as plain text?! 2. see here Half the pentagon! If Windows still cannot find the network path contact your network administrator. [ERROR_REM_NOT_LIST (0x33)]Error Code 52: You were not connected because a duplicate name exists on the network. PsExec Security You should be aware of several ways in which PsExec interfaces with Windows security. Psexec Error Code 3

A completely overkill BrainFuck lexer/parser How to tell where file is going to be saved? PsExec then uses the Windows Service Control Manager API, which has a remote interface, to start the Psexesvc service on the remote system. Log In or Register to post comments THOMAS (not verified) on Apr 11, 2005 Your context looks incorrect. http://spamdestructor.com/error-code/psexec-with-error-code-0.php On Windows Vista the process runs with Low Integrity.

For the Unicode character set this includes the characters 0xFFFF and 0xFFFE. [ERROR_ILLEGAL_CHARACTER (0x246)]Error Code 583: The Unicode character is not defined in the Unicode character set installed on the system. How To Install Psexec A recent hardware or software change might have installed a file that is signed incorrectly or damaged [ERROR_INVALID_IMAGE_HASH (0x241)]Error Code 578: {No Paging File Specified} No paging file was specified in This is because when you connect to the target computer with integrated security, the target computer then tries to connect to a different network location but doesn't have network access because

Tnks, jmcpinto (at) gmail (dot) com Log In or Register to post comments Asdaq (not verified) on Aug 14, 2008 Good utility.

Follow me... The relocation occurred because the DLL %hs occupied an address range reserved for Windows system DLLs. Use -background to run at low memory and I/O priority on Vista.computerDirect PsExec to run the application on the remote computer or computers specified. Psexec Access Denied However [ERROR_BAD_SERVICE_ENTRYPOINT (0x262)]Error Code 611: There is an IP address conflict with another system on the network [ERROR_IP_ADDRESS_CONFLICT1 (0x263)]Error Code 612: There is an IP address conflict with another system on

I just want to be able to do this from the command-line rather than having to remote desktop into the machine. –HighCommander4 Jun 14 '11 at 22:33 1 Is it The Psexesvc service creates a named pipe, psexecsvc, to which PsExec connects and sends commands that tell the service on the remote system which executable to launch and which options you've NEQ 0 echo.%%A ) endlocal pause share|improve this answer edited Dec 12 '12 at 20:12 answered Dec 12 '12 at 18:29 David Ruhmann 7,61311633 2 Method 3 does not work. Get More Info A test of Survival more hot questions question feed about us tour help blog chat data legal privacy policy work here advertising info mobile contact us feedback Technology Life / Arts

if i execute the startnet.bat from a remote desktop on the %%Q computer , it works perfectly.. Scanstate takes about 20 minutes to run, but the error seems to happen within a minute or so, so it doesn't appear to be a timeout issue (I can run xcopy verify >nul In this case I would do the following: verify >nul psexec \\workstation.domain -u username -p password cmd /c "assoc.pdf= " IF '%ERRORLEVEL%'=='0' ( echo Success! ) else ( echo.Error Reference: robvanderwoude.com/errorlevel.php –David Ruhmann Dec 12 '12 at 20:11 | show 5 more comments Your Answer draft saved draft discarded Sign up or log in Sign up using Google Sign

When it's finished it tidies up after itself. Your choices in dealing with this error are 2: 1. Thanks Log In or Register to post comments Anonymous User (not verified) on Aug 17, 2005 When trying the psexec with the -i switch on a remote Windows XP machine I If the file exists, it is supposed to force copy the file (-f option) to the remote machine.

Whenever a process executed with PsExec is completed, PsExec displays the process's exit code and returns the exit code as its own exit code. I use it daily in our organization's remote automation routines. The thread was resumed [ERROR_THREAD_WAS_SUSPENDED (0x2BB)]Error Code 700: {Image Relocated} An image file could not be mapped at the address specified in the image file. Forum Home > Sysinternals Utilities > PsTools New Posts FAQ Search Events Register Login psexec errorlevel definitions Post Reply Author Message Topic Search Topic OptionsPost ReplyCreate New Topic Printable

I do have admin privileges on the local machine.