Home > Post Error > Post Error 1719 Controller Failure

Post Error 1719 Controller Failure

Contents

I'm suspecting its the raid controller itself or the firmware running on said raid controller. 3 Jalapeno OP Pctaco May 1, 2015 at 8:06 UTC George1421 wrote:Denis Kelley One of our engineers ended arguing with someone on the phone for a couple of hours, repeatedly trying to explain that a packet capture wouldn't matter, because literally nothing was hooked If the condition persists, then replace the controller. Join & Ask a Question Need Help in Real-Time? http://spamdestructor.com/post-error/post-error-1719.php

Sign up for Subscriber's Choice at the following URL: Proactive Updates Subscription Form . Privacy Policy Site Map Support Terms of Use HomeChange ViewPrint 1719-Slot z Drive Array - A controller failure event occurred prior to this power-up (previous lock-up code = 0x####) Audible Please type your message and try again. 1 2 Previous Next 16 Replies Latest reply: Nov 17, 2008 3:26 AM by qboy Go to original post This content has been marked We Acted. check these guys out

A Controller Failure Event Occurred Prior To This Power Up 0x13

Modern PSU's with active PFC and very high eficiency (80+) are common in home computers, finally global vendors push them into server world to save energy...Jan 0 Kudos Reply BrightMinds Frequent An HP ProLiant Gen9 server may stop responding and, on the reboot, display the following 1719 POST error message: 1719-Slot 0 Drive Array - A controller failure event occurred prior to The information in this document is subject to change without notice. Connect with top rated Experts 21 Experts available now in Live!

No array errors. I understand your frustration at what happened. Current Customers and Partners Log in for full access Log In New to Red Hat? Previous Lockup Code 0x13 Magari con un config diverse sei forse più fortunato.---Had another crash today: ESX 4.1 was running smoothly and then a nice SCSI error halted the server.

i.e. Post Error 1719 P410i They finally escalated the issue (turned out that this was a 'known bug' in that version of the firmware...which was still available as the stable release on their site at the Last option I would also consider is the backplane that the HDD's plug into and on the other side the SAS cables plug into it. http://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-c01917689&sp4ts.oid=1157688 Very helpful Somewhat helpful Not helpful End of content United StatesHewlett Packard Enterprise International Start of Country Selector content Select Your Country/Region and Language Click or use the tab key to

In our testing, applying the recommended firmware on servers with this configuration will cause the server to freeze at post. Post Error 1719 P420i Was the information on this page helpful? running more VMs than would be possibly with gigabit. 1 Sonora OP Nick.J May 4, 2015 at 8:20 UTC Is the Array Controller integrated? Join the community of 500,000 technology professionals and ask your questions.

Post Error 1719 P410i

Covered by US Patent. https://community.spiceworks.com/topic/928470-hp-support-issues The fix was to update both the SmartArray and the Expander card firmware at the same time. A Controller Failure Event Occurred Prior To This Power Up 0x13 Now, the server hangs once or twice a week, most of the time in the weekends, ESX is unresponsive except for the the ALT-F11 screen: this gets filled with SCSI errors. Post Error: 1719-a Show 16 replies 15.

not integrated on the motherboard), then unseat it and reseat it (with the power off). http://spamdestructor.com/post-error/post-error-1719-p410i.php Netgear support was insistent that they needed a packet capture uploaded before they would look at the issue/try to find a root cause. Netgear support was insistent that they needed a packet capture uploaded before they would look at the issue/try to find a root cause. Featured Post How to improve team productivity Promoted by Quip, Inc Quip adds documents, spreadsheets, and tasklists to your Slack experience - Elevate ideas to Quip docs - Share Quip docs Drive Array Controller Failure (slot 0)

This was narrowed down to a possible UPS issue (see http://www.geakeit.co.uk/2010/11/04/review-avoid-the-hp-dl380-g7/).UPS replaced (at significant cost) the server now BSODs with 0xF4.I've installed the latest PSP and been through the entire device This issue will occur as a result of an anomaly when multiple threads attempt to access the same memory at the same time. Spent â ¬ 8000 on a server that randomly hangs with SCSI problems. have a peek here When it does initialize (normally following a further forced reboot) it displays post error 1719 (controller failure) and lockup code 0x13. 0 Kudos Reply Jan Soska Honored Contributor [Founder] Options Mark

Hewlett Packard Enterprise Company and the names of Hewlett Packard Enterprise Company products referenced herein are trademarks of Hewlett Packard Enterprise Company in the United States and other countries. Hp Post Error 1719 P410i I'm suspecting its the raid controller itself or the firmware running on said raid controller. Suggested Solutions Title # Comments Views Activity Add user account for APC PowerChute Business Edition. 6 62 66d EXCHANGE 2007, STORAGE , DRIVE LETTERS 5 56 34d stirling engine recommendation or

Re: Came in this Morning and ESX shows not Responding.

Solution Unverified - Updated 2014-01-01T03:29:40+00:00 - English No translations currently exist. I booted the server into windows and immediately started prime95. The errors I was getting are: 45 Critical POST Message 04/29/2015 18:17 04/29/2015 18:17 1 Option ROM POST Error: 1719-Slot 0 Drive Array - A controller failure event occurred prior to 1719 Slot 0 Drive Array A Controller Failure Event Occurred Prior To This Power-up We're desperate for something to fix as it's our dedicated SQL server! 0 Kudos Reply Simon.H Advisor Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to

I recommend you open up a ticket if you are having problems applying it.Bgrds,Finnur Like Show 0 Likes (0) Actions 2. You will get a user name prompt but you will never get the password prompt.I had this problem on an HP DL585.I have shut down all VM's from within their OS Edited May 1, 2015 at 8:32 UTC Tags: HP358,772 FollowersFollow Reply Subscribe View Best Answer RELATED TOPICS: how to fix "suspicious" hp msm765 It's official: HP will break itself in two Check This Out Provide feedback Please rate the information on this page to help us improve our content.

Any thoughts or suggestions? About Advertising Privacy Terms Help Sitemap × Join millions of IT pros like you Log in to Spiceworks Reset community password Agree to Terms of Service Connect with Or Sign up most people using the P410i controller on the G6's would only have had a maximum of 512MB BBWC by default.I've had the issue twice again since, both on the same server Explore Labs Configuration Deployment Troubleshooting Security Additional Tools Red Hat Access plug-ins Red Hat Satellite Certificate Tool Red Hat Insights Increase visibility into IT operations to detect and resolve technical issues

Anyone with a solution? 0 Kudos Reply BrightMinds Frequent Advisor Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎11-11-2010 09:05 This was in a custom chassis that had the "special" flap to hold the cards in rather than screws to hold each card.  We sent the entire machine back and ordered Cloning makes an exact, complete copy of one hard disk drive (HDD) onto another d… MS Legacy OS Storage Software Windows OS Storage Hardware Storage Setup SMTP relay to office 365 Click on category "Firmware - Storage Controller." Locate, download, and install Smart Array xxxx or Host Bus Adapter Firmware Version 3.56 (or later).

Thanks in advance!!! If it's still unhappy, try running the drive array controller without RAM/Battery - I've seen that be the cause of a problem or two. We had a couple Netgear 10Gbe switches (for a cheapo VMware VSAN deployment) that wouldn't save configs after a reboot. Just be aware that bios update != raid controller firmware.

Click on category "Firmware - Storage Controller." Locate, download, and install Smart Array xxxx or Host Bus Adapter Firmware Version 3.56 (or later). Also, have you tried removing and re-inserting the controller and cables? See more RELATED PROJECTS Complete Office Build I was hired to build out a complete new company that was created to be the "IT Arm" of the CEO's asset companies. Thank you!

Larry 0 Question by:pathwayscsb Facebook Twitter LinkedIn Google LVL 10 Best Solution byCSIPComputing If the Drive Array Controller is in a physical slot (i.e. I created a quick Powershell script that would call WMI for monitor info. Home HP Support Issues by Pctaco on May 1, 2015 at 7:29 UTC | HP Hardware 0Spice Down Next: EliteDesk Came with a Win 10 Pro CD... Help Desk » Inventory » Monitor » Community » Red Hat Customer Portal Skip to main content Main Navigation Products & Services Back View All Products Infrastructure and Management Back Red

They finally escalated the issue (turned out that this was a 'known bug' in that version of the firmware...which was still available as the stable release on their site at the During booting, it shows 1719-Slot 3 Drive Array - A Controller failure event occurred prior to this power-up. (Previous lock up code = 0x91) Then it goes to PXE-E61 Media Test This was only offered as a default option on the G7's so I wonder if it is related to the problem...