asked 5 years ago viewed 92959 times active 3 months ago Related 2HP ProLiant server - multiple raid controllers?2Smart Array P600: Can't get drives recognized on port 2i4Slow parity initialization of Is there anything I can do to access the data on the old drives? So you're seeing this? "1779 - Slot X Drive Array - Logical drive(s) previously failed... ...Select "F1" to continue with logical drives disabled Select "F2" to accept data loss and to Action: Update the controller to the latest firmware version 1. Source

I was not able to re-enable the Raid array and the last thing that HP could recommend over the phone was to send out a replacement drive. If this message is displayed after Options ROMPaq is run, problems may have occurred while attempting to flash the ROM. Can you please list all your POST errors?   0 Anaheim OP Craig G UK Nov 4, 2013 at 3:30 UTC Sorry  - it is the 1779 error Run Array Diagnostics Utility (ADU) if previous positions are unknown. click site

Any one know of any good reliable data recovery companies in the UK, preferably East Midlands / South Yorkshire etc? It *should* have gone into recovery mode the moment that drive came out, and the IML should have logged an entry saying as much.If none of that happened when you removed Port 85 codes and iLO messagespage 131................................................................................................................................................................ To print the manual completely, please, download it.

i.e. your firmware is VERY old. 3.0 came out in March 2010 and the latest version is 6.40 so you should really consider looking at updating firmware on the controller, the system But some data was missed in the last backup, so I need to recover data from the drives in the original array. Restore your data...

The URL does work. –ewwhite Jul 1 at 9:00 add a comment| up vote 1 down vote Oof, this one should have been obvious. It shouldn't do that on a RAID 5. Sign up! Discover More This server (our file server) needed an upgrade.

Phoned HP support and spent an hour going through various tests etc using the SmartStart CD. See, it's the non-system disk error that worries me.  The server isn't seeing anything it can boot from. Boot up with the new drives removed. So I have been looking at data recovery solutions.

Movie about a board-game that asks the players touchy questions A movie about people moving at the speed of light What do your base stats do for your character other than http://systemmanager.ru/c00724721.en/11628.htm By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner The system returned: (22) Invalid argument The remote host or network may be down. Action: Be sure the system is always powered up and down correctly: When powering up the system, all external storage systems must be powered up before (or at the same time

Not sure it can get any worse but dont want to chance it. this contact form How do you say "you all" in Esperanto? You may get a better answer to your question by starting a new discussion. Don't show me this message again.

Please go to HP Support Center. If the problem still exists and a cache memory module is attached to the controller, replace the cache memory module and reboot the server. 1784-Slot X Drive Array Drive Failure. Boot up the server At this point, I get the following error: 1785-Slot 0 Drive Array Not Configured Drive positions appear to have changed. http://spamdestructor.com/post-error/post-error-1779-drive.php The drives also need some firmware updates.Drive 4 shows the last failure reason as "hot removed" which is probably when you pulled it, so that's to be expected, but drive 3

I've had great experiences with 3ware controllers in situations like this. Community ProLiant Servers (ML,DL,SL) CommunityCategoryBoardUsers turn on suggestions Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as These products are now supported by HP Inc.

And thanks for the link - the E200 manual I was reading was sparse on details. –Nic Feb 6 '11 at 0:16 The HP manual link is broken already.

Why don't browser DNS caches mitigate DDOS attacks on DNS providers? Generated Mon, 24 Oct 2016 08:42:30 GMT by s_wx1206 (squid/3.5.20) ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.10/ Connection And have you actually swapped the disks or have HP not sent one yet? 0 Anaheim OP Craig G UK Nov 4, 2013 at 3:15 UTC Huw, What On the next reboot, the RAID5 array reappeared as expected.

This will be more difficult to track in the logs. And we were the (un)lucky winners!      0 Mace OP Huw3481 Nov 4, 2013 at 2:57 UTC HD IT Solutions is an IT service provider. I had assumed that the RAID metadata stored on the disks would be sufficient to bring the old RAID array back online, but that doesn't seem to be the case. http://spamdestructor.com/post-error/post-error-1784-drive-array-drive-failure.php up vote 3 down vote favorite I have an HP ProLiant DL180 G5 server with a Smart Array E200 RAID controller.

Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking Get the data you need. End of content United StatesHewlett Packard Enterprise International Start of Country Selector content Select Your Country/Region and Language Click or use the tab key to select your country ArgentinaAustraliaBelgiqueBoliviaBrasilCanadaCanada-françaisČeská republikaChileColombiaDeutschlandEcuadorEspañaFranceIndiaIrelandItaliaMagyarországMéxicoNew ZealandÖsterreichParaguayPerúPolskaPortugalPuerto The backup is showing as being successful but I am nervous to say the least.

The RAID controller is refusing to recognize inserted drives as an array. TECHNOLOGY IN THIS DISCUSSION HP 358772 Followers Follow Hewlet Packard Join the Community! Run an ADU report and post it here if possible. 0 Kudos Reply ~sesh Esteemed Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to Join the community Back I agree Powerful tools you need, all for free.

Boot up the server and acknowledge errors about failed drives Insert new drives and create new RAID10 array Format new array and restore data from tape backup. Plus the HP guy never even mentioned this line of repair, so it makes me a bit twitchy. If drives have not been replaced, this message indicates an intermittent drive failure. It started with 8 x 250GB drives: 2 in RAID1 for the OS 5 in RAID5 for data 1 as a hot spare.

The system returned: (22) Invalid argument The remote host or network may be down. Please allow me to clarify this was not a rant about about the product or the support I received. ADU will help in identifying it. http://h20564.www2.hpe.com/hpsc/doc/public/display?docId=c01608507 share|improve this answer edited Jul 1 at 9:00 answered Feb 6 '11 at 0:10 ewwhite 152k47301578 Yep, that was it.

Again, sincere thanks. 0 Mace OP Huw3481 Nov 4, 2013 at 4:02 UTC HD IT Solutions is an IT service provider. Please try the following:Use a different search stringIf search was based on document ID, check document ID or switch to keyword search Change your search criteria selectionCheck your search string for From experience I know that Telephone support is difficult and without being able to have any visual clues you are at the mercy of what you are being told by the more hot questions question feed about us tour help blog chat data legal privacy policy work here advertising info mobile contact us feedback Technology Life / Arts Culture / Recreation Science